- Suspension Strand : Is the steel wire or stranded cable. molded into
the outer sheath parallel with the cable core as a suspension
strength member.
- Screen: A
alminium tape coated both side with polythene is applied
longitudinally with overlap over the cable core. The
laminated alumium tape is sealed at the overlap to prevent
moisture.
|
|
|
|
|
| >> Cable Aerial Self-supporting Telephone
Cables - Foam/Skin Insulation |
| ........................................................................................................................ |
- Application : Aerial
Voice frequency systems, Local and function circuit.
- Installation: Om
Pals, span length up to m.
- Standards: Generally
Compling to IEC60708 - 1
- Conductor : Solid
plain annealed high conductivity copper round wire of
nominal dia 0.32, 0.4, 0.5, 0.65, 0.90 mm. As per IEC
28 & ASTM B3.
- Insulation: Dual
insulation of cellular Polythene covered with a skin
high-density polyethylene compound and coloured as per
requirement (BS06234 ASTM D 1248).
- Pair: Two insulated
conductor of specified colours twisted together with
pre-dertermined lay to form a pair. In order to minimized
the crosstalk. 10/20 pairs stranded and to open helical
binder of Polyester/PP/PE tape of specified colours
applied to form a unit.
- Units(SU): Five
Nos, - of 10 pairs twisted together to form - 50 pair
super unit - OR
- Super Units (SU):
- Five Nos. - of 20 pairs units twisted together to
form 100 pair super unit.
- Each super unit have an open helical binder of Polyester
/ PP/PE tape of specified colour for identification.
- Spares pair added in each super unit as per requirements.
- Cabling : For cables
above 100 pairs cable the required number of super units
are stranded to form a cable core.
Optional: If required
- The cable core is fully filled with jelly (water
resistance compound) which is compatible with the
insulation.
- The filled cable core is wrapped with a tape and
the flodding compound is applied.
- Sheath: The cable
is sheated with Virgin black polythene compound and
confirming to the requirment of the specification.
- Identification and Marking: On the finished cable sheath / jacket the cable
identification and marking is done by embosing / printing
as per the requirment of customer / specification.
|
|
|